T1 - Flow injection determination of iodide ion in a photographic developing solution using iodide ion-selective electrode detector
AU - Masadome, Takashi
AU - Sonoda, Risa
AU - Asano, Yasukazu
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2000/9/5
Y1 - 2000/9/5
N2 - A potentiometric flow injection determination method for iodide ion in a photographic developing solution was proposed by utilizing a flow-through type iodide ion-selective electrode detector. The sensing membrane of the electrode was Ag2S-AgI membrane. The response of the electrode detector as a peak-shape signal was obtained for injected iodide ion in a photographic developing solution. A linear relationship in the subnernstian zone was found to exist between peak height and the concentration of the iodide ion in a photographic developing solution in a concentration range from 0 to 6.0 x 10-5 mol l-1. The relative standard deviation for ten injections of 2 x 10-5 mol l-1 iodide ion in a photographic developing solution was 0.96% and the sampling rate was approximately 12-13 samples h-1. The iodide ion could be determined under coexisting of an organic reducing reagent and inorganic electrolytes of high concentration in a photographic developing solution sample solution by the present method. (C) 2000 Elsevier Science B.V.
AB - A potentiometric flow injection determination method for iodide ion in a photographic developing solution was proposed by utilizing a flow-through type iodide ion-selective electrode detector. The sensing membrane of the electrode was Ag2S-AgI membrane. The response of the electrode detector as a peak-shape signal was obtained for injected iodide ion in a photographic developing solution. A linear relationship in the subnernstian zone was found to exist between peak height and the concentration of the iodide ion in a photographic developing solution in a concentration range from 0 to 6.0 x 10-5 mol l-1. The relative standard deviation for ten injections of 2 x 10-5 mol l-1 iodide ion in a photographic developing solution was 0.96% and the sampling rate was approximately 12-13 samples h-1. The iodide ion could be determined under coexisting of an organic reducing reagent and inorganic electrolytes of high concentration in a photographic developing solution sample solution by the present method. (C) 2000 Elsevier Science B.V.
KW - Flow injection analysis
KW - Iodide ion
KW - Iodide-selective electrode detector
KW - Photographic developing solution
UR - http://www.scopus.com/inward/record.url?scp=0034609472&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034609472&partnerID=8YFLogxK
U2 - 10.1016/S0039-9140(00)00483-5
DO - 10.1016/S0039-9140(00)00483-5
M3 - Article
AN - SCOPUS:0034609472
SN - 0039-9140
VL - 52
SP - 1123
EP - 1130
JO - Talanta
JF - Talanta
IS - 6
ER -