TY - GEN
T1 - High frame rate photoacoustic computed tomography using coded excitation
AU - Azuma, Masataka
AU - Zhang, Haichong K.
AU - Kondo, Kengo
AU - Namita, Takeshi
AU - Yamakawa, Makoto
AU - Shiina, Tsuyoshi
N1 - Publisher Copyright:
© 2015 SPIE.
PY - 2015
Y1 - 2015
N2 - Photoacoustic Computed Tomography (PACT) records signals from a wide range of angles to achieve uniform, highresolution images. A high-power laser is generally used for PACT, but the long acquisition time with a single probe is a problem due to the low pulse-repetition frequency (PRF). For PACT, this degrades image resolution and contrast because it is hard to scan with a small step interval. Moreover, in vivo measurement requires a fast image acquisition system to avoid motion artifacts. The problem can be resolved by using a high PRF laser, which provides only weak energy. Averaging measured signals many times can mitigate the low signal-to-noise issue, but the PRF is restricted by the acoustic time of flight, so this is a new source of measurement time increase. Here, we present the coded-excitation approach, which we previously proposed for linear scanning, to increase the PACT frame rate. Coded excitation irradiates temporally encoded pulses and enhances the signal amplitude through decoding. The PRF is thus not restricted to acoustic time of flight. Consequently, acquisition time can be shortened by increasing PRF, and the SNR increases for the same measurement time. To validate the proposed idea, we conducted experiments using a high PRF laser with a revolving motor and compared the performance of coded excitation to that of averaging. Results demonstrated that the contamination of a signal acquired from different angles was negligible, and that the scanning pitch was remarkably improved because the start point of decoding can be set in any code in the periodic sequence.
AB - Photoacoustic Computed Tomography (PACT) records signals from a wide range of angles to achieve uniform, highresolution images. A high-power laser is generally used for PACT, but the long acquisition time with a single probe is a problem due to the low pulse-repetition frequency (PRF). For PACT, this degrades image resolution and contrast because it is hard to scan with a small step interval. Moreover, in vivo measurement requires a fast image acquisition system to avoid motion artifacts. The problem can be resolved by using a high PRF laser, which provides only weak energy. Averaging measured signals many times can mitigate the low signal-to-noise issue, but the PRF is restricted by the acoustic time of flight, so this is a new source of measurement time increase. Here, we present the coded-excitation approach, which we previously proposed for linear scanning, to increase the PACT frame rate. Coded excitation irradiates temporally encoded pulses and enhances the signal amplitude through decoding. The PRF is thus not restricted to acoustic time of flight. Consequently, acquisition time can be shortened by increasing PRF, and the SNR increases for the same measurement time. To validate the proposed idea, we conducted experiments using a high PRF laser with a revolving motor and compared the performance of coded excitation to that of averaging. Results demonstrated that the contamination of a signal acquired from different angles was negligible, and that the scanning pitch was remarkably improved because the start point of decoding can be set in any code in the periodic sequence.
KW - Coded excitation
KW - High frame rate
KW - High-resolution images
KW - Photoacoustic computed tomography
UR - http://www.scopus.com/inward/record.url?scp=84928535877&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84928535877&partnerID=8YFLogxK
U2 - 10.1117/12.2079406
DO - 10.1117/12.2079406
M3 - Conference contribution
AN - SCOPUS:84928535877
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Photons Plus Ultrasound
A2 - Oraevsky, Alexander A.
A2 - Wang, Lihong V.
PB - SPIE
T2 - Photons Plus Ultrasound: Imaging and Sensing 2015
Y2 - 8 February 2015 through 10 February 2015
ER -