TY - JOUR
T1 - Long-range surface plasmon aptasensor for label-free monitoring of vancomycin
AU - Toma, Koji
AU - Satomura, Yui
AU - Iitani, Kenta
AU - Arakawa, Takahiro
AU - Mitsubayashi, Kohji
N1 - Funding Information:
This work was partly supported by the Japan Society for the Promotion of Science (JSPS, Japan) KAKENHI Grant Number JP 21H01335 ; the Ministry of Education, Culture, Sports, Science and Technology (MEXT, Japan) Special Funds for the Cooperative Research Project of Research Center for Biomedical Engineering .
Publisher Copyright:
© 2022 Elsevier B.V.
PY - 2023/2/15
Y1 - 2023/2/15
N2 - Vancomycin (VCM) causes poisoning symptoms at high concentrations; thus, therapeutic drug monitoring is recommended to measure and control blood levels regularly. However, blood analysis at regular intervals does not allow knowing the detailed temporal change in concentration. To address this challenge, we developed a long-range surface plasmon (LRSP) aptasensor for measuring VCM label-free and real-time by combining a sensitive LRSP sensor and a peptide aptamer with a VCM recognition site. First, three different biosensors for VCM were compared. One was prepared by immobilizing the peptide aptamer directly on (Direct-Apt) or via a self-assembled monolayer (SAM) on a gold surface (SAM-Apt). The other used anti-VCM antibodies immobilized on a gold surface via the SAM (SAM-Ab). The Direct-Apt showed larger sensor output to VCM than the other biosensors. The dynamic range for VCM was 0.78–100 μM, including the therapeutic range (6.9–13.8 μM). The Direct-Apt also showed the sensor output only from VCM among four different antibiotics, demonstrating the high selectivity for VCM. The VCM captured by the aptamer could be removed by rinsing with phosphate-buffered saline. The measurement was rapid, with 72- and 77-sec response and recovery times, allowing not only repeated but also real-time measurements. Finally, the Direct-Apt in 20% serum solutions showed comparable sensitivity to VCM in the buffer solution, indicating high capability for real-sample.
AB - Vancomycin (VCM) causes poisoning symptoms at high concentrations; thus, therapeutic drug monitoring is recommended to measure and control blood levels regularly. However, blood analysis at regular intervals does not allow knowing the detailed temporal change in concentration. To address this challenge, we developed a long-range surface plasmon (LRSP) aptasensor for measuring VCM label-free and real-time by combining a sensitive LRSP sensor and a peptide aptamer with a VCM recognition site. First, three different biosensors for VCM were compared. One was prepared by immobilizing the peptide aptamer directly on (Direct-Apt) or via a self-assembled monolayer (SAM) on a gold surface (SAM-Apt). The other used anti-VCM antibodies immobilized on a gold surface via the SAM (SAM-Ab). The Direct-Apt showed larger sensor output to VCM than the other biosensors. The dynamic range for VCM was 0.78–100 μM, including the therapeutic range (6.9–13.8 μM). The Direct-Apt also showed the sensor output only from VCM among four different antibiotics, demonstrating the high selectivity for VCM. The VCM captured by the aptamer could be removed by rinsing with phosphate-buffered saline. The measurement was rapid, with 72- and 77-sec response and recovery times, allowing not only repeated but also real-time measurements. Finally, the Direct-Apt in 20% serum solutions showed comparable sensitivity to VCM in the buffer solution, indicating high capability for real-sample.
KW - Aptasensor
KW - Surface plasmon
KW - Therapeutic drug monitoring
KW - Vancomycin
UR - http://www.scopus.com/inward/record.url?scp=85144638163&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144638163&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2022.114959
DO - 10.1016/j.bios.2022.114959
M3 - Article
C2 - 36502716
AN - SCOPUS:85144638163
SN - 0956-5663
VL - 222
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
M1 - 114959
ER -