T1 - Measurement of equivalent continuous A-weighted sound pressure level of driving sound of three tesla MRI equipment
AU - Chikai, Masataka
AU - Shimono, Yasuhiro
AU - Muto, Kenji
AU - Shibayama, Hideo
AU - Yagi, Kazuo
AU - Onodera, Toshiyuki
PY - 2010/12/1
Y1 - 2010/12/1
N2 - Magnetic resonance imaging (MRI) equipment is important in medical diagnosis. The equipment utilizes a technology of tomography by the nuclear magnetic resonance phenomenon for imaging. Driving sound of MRI equipment is loud and it is caused by using the gradient magnetic field controlled by imaging sequence. It generates loud sound which depends on imaging sequence. The sound pressure level of the driving sound is over 100 dB sometimes and it makes the ear-protector necessary. There are some researches of the driving sound. In this paper, this paper shows the measurement result of equivalent continuous A-weighted sound pressure level of distribution in the three tesla MRI equipment which is Philip Achieva 3.0T X-series. Number of measurement point is 21 on the table; the 15 points located inside of the bore and the 6 points located outside of the bore. Imaging sequences of the measurement sound are slice positioning, T2 weighted imaging (T2W) and Echo planar imaging (EPI). The measurement data length is 30.04 seconds. The result showed that the driving sound of each imaging sequences on the table was loud. The maximum equivalent continuous A-weighted sound pressure level (LAeq) of slice positioning, T2W and EPI were 114.7 dB, 106.0 dB, 114.3 dB respectively. These values were larger than driving sound of 1.5 tesla MRI equipment. The maximum value of instantaneous sound pressure was 123.9 dB in the three sequences of the 3 tesla MRI equipment. So, it shows the instantaneous value is important parameter.
AB - Magnetic resonance imaging (MRI) equipment is important in medical diagnosis. The equipment utilizes a technology of tomography by the nuclear magnetic resonance phenomenon for imaging. Driving sound of MRI equipment is loud and it is caused by using the gradient magnetic field controlled by imaging sequence. It generates loud sound which depends on imaging sequence. The sound pressure level of the driving sound is over 100 dB sometimes and it makes the ear-protector necessary. There are some researches of the driving sound. In this paper, this paper shows the measurement result of equivalent continuous A-weighted sound pressure level of distribution in the three tesla MRI equipment which is Philip Achieva 3.0T X-series. Number of measurement point is 21 on the table; the 15 points located inside of the bore and the 6 points located outside of the bore. Imaging sequences of the measurement sound are slice positioning, T2 weighted imaging (T2W) and Echo planar imaging (EPI). The measurement data length is 30.04 seconds. The result showed that the driving sound of each imaging sequences on the table was loud. The maximum equivalent continuous A-weighted sound pressure level (LAeq) of slice positioning, T2W and EPI were 114.7 dB, 106.0 dB, 114.3 dB respectively. These values were larger than driving sound of 1.5 tesla MRI equipment. The maximum value of instantaneous sound pressure was 123.9 dB in the three sequences of the 3 tesla MRI equipment. So, it shows the instantaneous value is important parameter.
UR - http://www.scopus.com/inward/record.url?scp=84869104475&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84869104475&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84869104475
SN - 9781617827457
T3 - 20th International Congress on Acoustics 2010, ICA 2010 - Incorporating Proceedings of the 2010 Annual Conference of the Australian Acoustical Society
SP - 2716
EP - 2719
BT - 20th International Congress on Acoustics 2010, ICA 2010 - Incorporating Proceedings of the 2010 Annual Conference of the Australian Acoustical Society
T2 - 20th International Congress on Acoustics 2010, ICA 2010 - Incorporating the 2010 Annual Conference of the Australian Acoustical Society
Y2 - 23 August 2010 through 27 August 2010
ER -