Microfluidic long-term gradient generator with axon separation prototyped by 185 nm diffused light photolithography of SU-8 photoresist

Nobuyuki Futai, Makoto Tamura, Tomohisa Ogawa, Masato Tanaka

Research output: Contribution to journalArticlepeer-review

5 Citations (Scopus)

Abstract

We have developed a cast microfluidic chip for concentration gradient generation that contains a thin (~5 μm2 cross-sectional area) microchannel. The diffusion of diffused 185 nm ultraviolet (UV) light from an inexpensive low-pressure mercury lamp exposed a layer of the SU-8 photoresist from the backside and successfully patterned durable 2 μm-high microchannel mold features with smooth bell-shaped sidewalls. The thin channel had appropriate flow resistance and simultaneously satisfied both the rapid introduction of test substance and long-term maintenance of gradients. The average height and width at the half height of the channel, defined by a 2 μm-wide line mask pattern, were 2.00 ± 0.19 μm, and 2.14 ± 0.89 μm, respectively. We were able to maintain the concentration gradient of Alexa Fluor 488 fluorescent dye inside or at the exit of the thin microchannel in an H-shaped microfluidic configuration for at least 48 h. We also demonstrated the cultivation of chick embryo dorsal root ganglion neuronal cells for 96 h, and the directional elongation of axons under a nerve growth factor concentration gradient.

Original languageEnglish
Article number9
JournalMicromachines
Volume10
Issue number1
DOIs
Publication statusPublished - 2019 Jan 1

Keywords

  • Axon elongation
  • Microchannel
  • Microfluidic gradient generator
  • Prototyping
  • SU-8

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Microfluidic long-term gradient generator with axon separation prototyped by 185 nm diffused light photolithography of SU-8 photoresist'. Together they form a unique fingerprint.

Cite this