TY - JOUR
T1 - Muscle quality indices separately associate with joint-level power-related measures of the knee extensors in older males
AU - Hirata, Kosuke
AU - Ito, Mari
AU - Nomura, Yuta
AU - Kawashima, Chiho
AU - Tsuchiya, Yuma
AU - Ooba, Kosuke
AU - Yoshida, Tsukasa
AU - Yamada, Yosuke
AU - Power, Geoffrey A.
AU - Tillin, Neale A.
AU - Akagi, Ryota
N1 - Funding Information:
This work was supported by JSPS KAKENHI Grant number JP17KK0174 (to RA).
Publisher Copyright:
© 2022, The Author(s).
PY - 2022/10
Y1 - 2022/10
N2 - Purpose: The purpose of this study was to investigate associations of muscle quality indices with joint-level power-related measures in the knee extensors of thirty-two older males (65–88 years). Methods: Muscle quality indices included: echo intensity, ratio of intracellular- to total water content (ICW/TW), and specific muscle strength. Echo intensity was acquired from the rectus femoris (EIRF) and vastus lateralis (EIVL) by ultrasonography. ICW/TW was computed from electrical resistance of the right thigh obtained by bioelectrical impedance spectroscopy. Specific muscle strength was determined as the normalized maximal voluntary isometric knee extension (MVIC) torque to estimated knee extensor volume. Isotonic maximal effort knee extensions with a load set to 20% MVIC torque were performed to obtain the knee extension power-related measures (peak power, rate of power development [RPD], and rate of velocity development [RVD]). Power and RPD were normalized to MVIC. Results: There were no significant correlations between muscle quality indices except between EIRF and EIVL (|r|≤ 0.253, P ≥ 0.162). EIRF was negatively correlated with normalized RPD and RVD (r ≤ − 0.361, P ≤ 0.050). ICW/TW was positively correlated with normalized peak power (r = 0.421, P = 0.020). Specific muscle strength was positively correlated with absolute peak power and RPD (r ≥ 0.452, P ≤ 0.012). Conclusion: Knee extension power-related measures were lower in participants with higher EI, lower ICW/TW, and lower specific muscle strength, but the muscle quality indices may be determined by independent physiological characteristics.
AB - Purpose: The purpose of this study was to investigate associations of muscle quality indices with joint-level power-related measures in the knee extensors of thirty-two older males (65–88 years). Methods: Muscle quality indices included: echo intensity, ratio of intracellular- to total water content (ICW/TW), and specific muscle strength. Echo intensity was acquired from the rectus femoris (EIRF) and vastus lateralis (EIVL) by ultrasonography. ICW/TW was computed from electrical resistance of the right thigh obtained by bioelectrical impedance spectroscopy. Specific muscle strength was determined as the normalized maximal voluntary isometric knee extension (MVIC) torque to estimated knee extensor volume. Isotonic maximal effort knee extensions with a load set to 20% MVIC torque were performed to obtain the knee extension power-related measures (peak power, rate of power development [RPD], and rate of velocity development [RVD]). Power and RPD were normalized to MVIC. Results: There were no significant correlations between muscle quality indices except between EIRF and EIVL (|r|≤ 0.253, P ≥ 0.162). EIRF was negatively correlated with normalized RPD and RVD (r ≤ − 0.361, P ≤ 0.050). ICW/TW was positively correlated with normalized peak power (r = 0.421, P = 0.020). Specific muscle strength was positively correlated with absolute peak power and RPD (r ≥ 0.452, P ≤ 0.012). Conclusion: Knee extension power-related measures were lower in participants with higher EI, lower ICW/TW, and lower specific muscle strength, but the muscle quality indices may be determined by independent physiological characteristics.
KW - Bioelectrical impedance spectroscopy
KW - Echo intensity
KW - Intracellular water
KW - Rate of power development
KW - Rate of velocity development
KW - Specific muscle strength
UR - http://www.scopus.com/inward/record.url?scp=85134536475&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134536475&partnerID=8YFLogxK
U2 - 10.1007/s00421-022-05005-2
DO - 10.1007/s00421-022-05005-2
M3 - Article
C2 - 35849183
AN - SCOPUS:85134536475
SN - 1439-6319
JO - European Journal of Applied Physiology
JF - European Journal of Applied Physiology
ER -