On-site verification for installation and permeability of H-jointed SPSPs with H-H joints

S. Inazumi, M. Kimura

Research output: Chapter in Book/Report/Conference proceedingConference contribution

7 Citations (Scopus)

Abstract

In this research, we conducted field installation and permeability tests for H-jointed SPSPs with H-H joints for their first application in the field; the tests were conducted in December 2006. Through a series of field installation and permeability tests, we verified the various factors considered in the construction field when using SPSP methods. These factors include the field installation and water interception performance of H-jointed SPSPs with H-H joints as well as their performance with regard to construction vibration, construction noise, welding and pullout. In this paper, the field installation and water interception performance of H-jointed SPSPs with H-H joints are reported on the basis of the results obtained from the field installation and permeability tests.

Original languageEnglish
Title of host publicationProceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering
Subtitle of host publicationThe Academia and Practice of Geotechnical Engineering
Pages2540-2543
Number of pages4
DOIs
Publication statusPublished - 2009 Dec 1
Externally publishedYes
Event17th International Conference on Soil Mechanics and Geotechnical Engineering, ICSMGE 2009 - Alexandria, Egypt
Duration: 2009 Oct 52009 Oct 9

Publication series

NameProceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering: The Academia and Practice of Geotechnical Engineering
Volume3

Other

Other17th International Conference on Soil Mechanics and Geotechnical Engineering, ICSMGE 2009
Country/TerritoryEgypt
CityAlexandria
Period09/10/509/10/9

Keywords

  • Field installation
  • Field permeability
  • H-H joint
  • H-jointed steel pipe sheet pile

ASJC Scopus subject areas

  • Geotechnical Engineering and Engineering Geology

Fingerprint

Dive into the research topics of 'On-site verification for installation and permeability of H-jointed SPSPs with H-H joints'. Together they form a unique fingerprint.

Cite this