Verification of fall detection sensor

Tadahiro Hasegawa, Hiroki Yokota

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

We report about a fall-detection sensor system that detects the beginning of a fall. The fall-detection sensor system monitors the human pulse as a vital sign, acceleration, and angular velocity. The fall-detection algorithm using these signals enables us to detect the beginning of a fall correctly. Especially, the fall detection algorithm using the vital sign was able to distinguish between a case in which persons did not fall down due to keep their balance although the fall began and a case in which persons fell.

Original languageEnglish
Pages (from-to)1089-1091
Number of pages3
JournalJournal of Robotics and Mechatronics
Volume24
Issue number6
DOIs
Publication statusPublished - 2012 Dec

Keywords

  • Accelerometer
  • Angular velocity
  • Fall-detection
  • Pulse wave

ASJC Scopus subject areas

  • Computer Science(all)
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Verification of fall detection sensor'. Together they form a unique fingerprint.