A Reconstruction Algorithm of Body Sections with Opaque Obstructions

Jong Soo Choi, Koichi Ogawa, Masato Nakajima, Shin'ichi Yuta

研究成果: Article査読

12 被引用数 (Scopus)

抄録

A new ultrasonic computed tomography (CT) algorithm, which reconstructs tomograms from projections with data-missing parts due to opaque obstructions such as bone or gas in the body, is proposed. This algorithm estimates the missing information by iterative modifications on the projectional axis and the reconstructed image plane, respectively, using a priori information, i.e., the object's crosssection boundary and the outline of the opaque obstruction. The results of computer simulation and basic experiment show that 5–6 iterations give a good reconstructed image.

本文言語English
ページ(範囲)143-150
ページ数8
ジャーナルIEEE Transactions on Sonics and Ultrasonics
29
3
DOI
出版ステータスPublished - 1982 5月

ASJC Scopus subject areas

  • 工学(全般)

フィンガープリント