TY - GEN
T1 - Basic research on the upper limb patient simulator
AU - Fujisawa, Tomohiro
AU - Takagi, Motoki
AU - Takahashi, Yoshiyuki
AU - Inoue, Kaoru
AU - Terada, Takafumi
AU - Kawakami, Yukio
AU - Komeda, Takashi
PY - 2007
Y1 - 2007
N2 - In the field of rehabilitation, physical therapist plays an important role to resume the social life from disease and physical handicap. However, they can obtain their skills only from their practical experiences. The trainee of the physical therapist can earn the experience only from the clinical practical training, and the opportunity is limited. Therefore, we have been developing the upper limb patient simulator, which reproduce the stiffness of elbow joint to allow trainees to increase the opportunities to obtain the exercise of the physical therapy. The system reproduces the diseases by generating stiffness of the elbow joint, when the trainee is trying to flexion the elbow joint of the patient. In this paper, we tried to reproduce the stiffness of Spasticity, that is often seen the patients of stroke and shoulder paralyzed. In addition, we evaluated reproducibility of the stiffness with out system.
AB - In the field of rehabilitation, physical therapist plays an important role to resume the social life from disease and physical handicap. However, they can obtain their skills only from their practical experiences. The trainee of the physical therapist can earn the experience only from the clinical practical training, and the opportunity is limited. Therefore, we have been developing the upper limb patient simulator, which reproduce the stiffness of elbow joint to allow trainees to increase the opportunities to obtain the exercise of the physical therapy. The system reproduces the diseases by generating stiffness of the elbow joint, when the trainee is trying to flexion the elbow joint of the patient. In this paper, we tried to reproduce the stiffness of Spasticity, that is often seen the patients of stroke and shoulder paralyzed. In addition, we evaluated reproducibility of the stiffness with out system.
UR - http://www.scopus.com/inward/record.url?scp=48349136609&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=48349136609&partnerID=8YFLogxK
U2 - 10.1109/ICORR.2007.4428405
DO - 10.1109/ICORR.2007.4428405
M3 - Conference contribution
AN - SCOPUS:48349136609
SN - 1424413206
SN - 9781424413201
T3 - 2007 IEEE 10th International Conference on Rehabilitation Robotics, ICORR'07
SP - 48
EP - 51
BT - 2007 IEEE 10th International Conference on Rehabilitation Robotics, ICORR'07
T2 - 2007 IEEE 10th International Conference on Rehabilitation Robotics, ICORR'07
Y2 - 12 June 2007 through 15 June 2007
ER -