TY - JOUR
T1 - Contact force controlled orthoses made of nitinol shape memory alloy wire for the treatment of malformed ears
AU - Hanafusa, A.
AU - Takahashi, H.
AU - Sekiguchi, Y.
AU - Nozaki, M.
AU - Dohi, T.
PY - 2006/6
Y1 - 2006/6
N2 - Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.
AB - Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.
KW - Finite element analysis
KW - Malformed ears
KW - Orthosis
KW - Shape memory alloy wire
UR - http://www.scopus.com/inward/record.url?scp=33748955183&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33748955183&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:33748955183
SN - 1861-6410
VL - 1
SP - 321
EP - 323
JO - Computer-Assisted Radiology and Surgery
JF - Computer-Assisted Radiology and Surgery
IS - SUPPL. 7
ER -