T1 - Development of non-contact respiratory monitoring system for newborn using a FG vision sensor
AU - Kurami, Yoshiyuki
AU - Itoh, Yushi
AU - Natori, Michiya
AU - Ohzeki, Kazuo
AU - Aoki, Yoshimitsu
PY - 2010
Y1 - 2010
N2 - In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and Sp02 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.
AB - In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and Sp02 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.
KW - 3D measurement
KW - Active stereo vision
KW - FG vision sensor
KW - Non-contact respiratory monitoring
UR - http://www.scopus.com/inward/record.url?scp=78049442633&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78049442633&partnerID=8YFLogxK
U2 - 10.1541/ieejeiss.130.1581
DO - 10.1541/ieejeiss.130.1581
M3 - Article
AN - SCOPUS:78049442633
SN - 0385-4221
VL - 130
SP - 1581-1587+11
JO - IEEJ Transactions on Electronics, Information and Systems
JF - IEEJ Transactions on Electronics, Information and Systems
IS - 9
ER -