TY - JOUR
T1 - Electron transfer mediator micro-biosensor fabrication by organic plasma process
AU - Hiratsuka, Atsunori
AU - Kojima, Ken Ichi
AU - Muguruma, Hitoshi
AU - Lee, Kyong Hoon
AU - Suzuki, Hiroaki
AU - Karube, Isao
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2005/12/15
Y1 - 2005/12/15
N2 - We propose a new strategy for constructing a mediator-type biosensor as a Bio-MicroElectroMechanical Systems (BioMEMS) application. A vinylferrocene plasma-polymerized film (PPF) was deposited directly onto the surface of an electrode under dry conditions. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly crosslinked network structure. This technique, capable of polymeric deposition of any kind of monomer, can also serve the purpose of anti-fouling coating, or layer-to-layer interface creation. With a subsequent plasma process, additional polymeric layer of hydrophilic acetonitrile was superimposed onto the existing vinylferrocene-PPF surface to offer crucial features such that the wettability could be adjusted for a better electron transfer, and amino functional groups could be attached to immobilize a large amount of enzyme. Based upon this scheme, the device fabrication could be designed in a manner that the whole procedure was made up of dry wafer-handling processes, which is compatible with mass production. A prototype device was fabricated to have an array of needle-shaped amperometric micro-biosensors. The resultant thin polymer layer carried a large number of the mediator molecules, accomplishing a lower overpotential (+410 mV) and a rapid response time (<5 s). Stressing the advantages of the plasma polymerization process together with some additional features accomplished in our device fabrication, we would discuss new possibilities in the field of BioMEMS.
AB - We propose a new strategy for constructing a mediator-type biosensor as a Bio-MicroElectroMechanical Systems (BioMEMS) application. A vinylferrocene plasma-polymerized film (PPF) was deposited directly onto the surface of an electrode under dry conditions. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly crosslinked network structure. This technique, capable of polymeric deposition of any kind of monomer, can also serve the purpose of anti-fouling coating, or layer-to-layer interface creation. With a subsequent plasma process, additional polymeric layer of hydrophilic acetonitrile was superimposed onto the existing vinylferrocene-PPF surface to offer crucial features such that the wettability could be adjusted for a better electron transfer, and amino functional groups could be attached to immobilize a large amount of enzyme. Based upon this scheme, the device fabrication could be designed in a manner that the whole procedure was made up of dry wafer-handling processes, which is compatible with mass production. A prototype device was fabricated to have an array of needle-shaped amperometric micro-biosensors. The resultant thin polymer layer carried a large number of the mediator molecules, accomplishing a lower overpotential (+410 mV) and a rapid response time (<5 s). Stressing the advantages of the plasma polymerization process together with some additional features accomplished in our device fabrication, we would discuss new possibilities in the field of BioMEMS.
KW - Electron transfer mediator
KW - Enzyme
KW - Ferrocene
KW - Glucose biosensor
KW - Plasma-polymerized film
UR - http://www.scopus.com/inward/record.url?scp=27444440763&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=27444440763&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2005.03.002
DO - 10.1016/j.bios.2005.03.002
M3 - Article
C2 - 16257665
AN - SCOPUS:27444440763
SN - 0956-5663
VL - 21
SP - 957
EP - 964
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 6
ER -