TY - GEN
T1 - Frequency resolution and accuracy improvement of a GaP CW THz spectrometer
AU - Sasaki, Tetsuo
AU - Tanabe, Tadao
AU - Nishizawa, Jun Ichi
N1 - Funding Information:
This work was partly supported by Grants-in-Aid for Scientific Research (B) (No. 16H03882) from the Japan Society for the Promotion of Science.
Publisher Copyright:
© Springer International Publishing AG 2017.
PY - 2017
Y1 - 2017
N2 - High resolution terahertz (THz) spectroscopy is available for sensitive gas detection and also useful for vibrational mode analysis of organic molecules. We developed a widely frequency tunable (0.1-7.5 THz), monochromatic coherent THz-wave Signal Generator on the basis of difference frequency generation (DFG) in a GaP crystal via excitation of phonon-polariton mode under small-angle non-collinear phase matching condition. The pump beams for DFG were supplied from semiconductor lasers as seed beams after amplification by fiber amplifiers. Then we applied it as a light source for a high resolution and high accuracy THz spectrometer. Combining with a superconducting Transition Edge Sensor (TES) bolometer cooled by a pulse tube refrigerator, a non-stop spectrometer system was realized. The system had advantages of high stability, small size, easy operation and maintenance free in the lifetime of the pump lasers. As frequency resolution and accuracy were limited by those of pump laser beams, we have newly developed a frequency control system for two beams at the same time. Frequency resolution of 8 MHz constant in whole the frequency tunable range and absolute accuracy of better than 3 MHz were evaluated by the measurements of water vapor absorptions in vacuum.
AB - High resolution terahertz (THz) spectroscopy is available for sensitive gas detection and also useful for vibrational mode analysis of organic molecules. We developed a widely frequency tunable (0.1-7.5 THz), monochromatic coherent THz-wave Signal Generator on the basis of difference frequency generation (DFG) in a GaP crystal via excitation of phonon-polariton mode under small-angle non-collinear phase matching condition. The pump beams for DFG were supplied from semiconductor lasers as seed beams after amplification by fiber amplifiers. Then we applied it as a light source for a high resolution and high accuracy THz spectrometer. Combining with a superconducting Transition Edge Sensor (TES) bolometer cooled by a pulse tube refrigerator, a non-stop spectrometer system was realized. The system had advantages of high stability, small size, easy operation and maintenance free in the lifetime of the pump lasers. As frequency resolution and accuracy were limited by those of pump laser beams, we have newly developed a frequency control system for two beams at the same time. Frequency resolution of 8 MHz constant in whole the frequency tunable range and absolute accuracy of better than 3 MHz were evaluated by the measurements of water vapor absorptions in vacuum.
UR - http://www.scopus.com/inward/record.url?scp=84989832707&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84989832707&partnerID=8YFLogxK
U2 - 10.1007/978-3-319-46490-9_5
DO - 10.1007/978-3-319-46490-9_5
M3 - Conference contribution
AN - SCOPUS:84989832707
SN - 9783319464893
T3 - Advances in Intelligent Systems and Computing
SP - 33
EP - 38
BT - Recent Global Research and Education
A2 - Jabłoński, Ryszard
A2 - Szewczyk, Roman
PB - Springer Verlag
T2 - 15th International Conference on Global Research and Education, INTER-ACADEMIA 2016
Y2 - 26 September 2016 through 28 September 2016
ER -