抄録
Extraction chromatography flow-sheet employing octyl(phenyl)-N,N-diisobutylcarbonoylmethylphosphine oxide and bis(2-ethylhexyl) hydrogen phosphate extractants for trivalent minor actinide recovery was modified to improve column separation performance. Excellent trivalent minor actinides recovery performance was obtained by column separation experiments on nitric acid solution containing the trivalent minor actinides and representative fission product elements, i.e. recovery yields > 93% with sufficient decontamination factors against the fission products. Those are the best performance which we have ever obtained by experiments inside hot cell.
本文言語 | English |
---|---|
ページ(範囲) | 1273-1277 |
ページ数 | 5 |
ジャーナル | Journal of Radioanalytical and Nuclear Chemistry |
巻 | 322 |
号 | 3 |
DOI | |
出版ステータス | Published - 2019 12月 1 |
ASJC Scopus subject areas
- 分析化学
- 原子力エネルギーおよび原子力工学
- 放射線学、核医学およびイメージング
- 汚染
- 分光学
- 公衆衛生学、環境および労働衛生
- 健康、毒物学および変異誘発