TY - JOUR
T1 - Investigation of design concept and basic performance of task air conditioning system for wide use
AU - Yanai, Takashi
AU - Akimoto, Takashi
PY - 2014/6
Y1 - 2014/6
N2 - Authors have developed a practical Task and Ambient Air Conditioning system which could respond to layout change of office. The system supplies air from a task unit installed in a partition, using pressure difference between underfloor and office room with a pressurization type under floor air-conditioning system as driving force. Performance experiments of the developed system in an early stage have been conducted using a mock-up to know a quantity required for air supply of a task unit. It was found that 25-35 CMH of supply air volume was obtained as maximum when pressure difference was 10-15 Pa, and it could be reduced to 5-8 CMH as minimum by adjusting the slide shutter for air volume control. In addition to that, by operating guide vanes for airflow direction adjustment, it was possible to control airflow direction from 0 to 45 degrees, and air velocity at a seat position was 0.3-0.4 m/s then. Field performance experiments of the system in a real office was also conducted with a thermal mannequin. It was confirmed that controllability of supply air volume and airflow direction of the system. Equivalent temperature (Teq) of each human body part was almost 28°C except head part that received direct air flow from task unit. It was confirmed that Teq of head part was 25°C. Results of questionnaire surveys against workers using task units in the office showed that almost all of votes were thermally comfort side.
AB - Authors have developed a practical Task and Ambient Air Conditioning system which could respond to layout change of office. The system supplies air from a task unit installed in a partition, using pressure difference between underfloor and office room with a pressurization type under floor air-conditioning system as driving force. Performance experiments of the developed system in an early stage have been conducted using a mock-up to know a quantity required for air supply of a task unit. It was found that 25-35 CMH of supply air volume was obtained as maximum when pressure difference was 10-15 Pa, and it could be reduced to 5-8 CMH as minimum by adjusting the slide shutter for air volume control. In addition to that, by operating guide vanes for airflow direction adjustment, it was possible to control airflow direction from 0 to 45 degrees, and air velocity at a seat position was 0.3-0.4 m/s then. Field performance experiments of the system in a real office was also conducted with a thermal mannequin. It was confirmed that controllability of supply air volume and airflow direction of the system. Equivalent temperature (Teq) of each human body part was almost 28°C except head part that received direct air flow from task unit. It was confirmed that Teq of head part was 25°C. Results of questionnaire surveys against workers using task units in the office showed that almost all of votes were thermally comfort side.
KW - Task and Ambient
KW - Thermal Environment
KW - Under Floor Air Conditioning
KW - Workspace Productivity
UR - http://www.scopus.com/inward/record.url?scp=84904974614&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84904974614&partnerID=8YFLogxK
U2 - 10.3130/aije.79.525
DO - 10.3130/aije.79.525
M3 - Article
AN - SCOPUS:84904974614
SN - 1348-0685
VL - 79
SP - 525
EP - 534
JO - Journal of Environmental Engineering
JF - Journal of Environmental Engineering
IS - 700
ER -