TY - JOUR
T1 - The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method
AU - Koike, Yoshikazu
AU - Kikura, Hiroshige
AU - Wada, Sanehiro
AU - Taishi, Tsuyoshi
AU - Aritomi, Masanori
AU - Mori, Michitsugu
PY - 2003/12/1
Y1 - 2003/12/1
N2 - An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.
AB - An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.
UR - http://www.scopus.com/inward/record.url?scp=4143069536&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=4143069536&partnerID=8YFLogxK
M3 - Conference article
AN - SCOPUS:4143069536
SN - 1051-0117
VL - 2
SP - 1451
EP - 1454
JO - Proceedings of the IEEE Ultrasonics Symposium
JF - Proceedings of the IEEE Ultrasonics Symposium
T2 - 2003 IEEE Ultrasonics Symposium - Proceedings
Y2 - 5 October 2003 through 8 October 2003
ER -